EITK2000
Kit for manual addressing, configuration, maintenance and diagnosis of systems based on ENEA series devices
The EITK2000 is a kit composed
of the EDRV2000 driver, the FireGenius-PRO software and a series of accessories
for connection and power supply.
The EDRV2000 driver, thanks to its ergonomic shape, provides an easy way of
performing the manual addressing operations related to addressable analogue
devices from the Enea series when you do not want to use the automatic
addressing function provided by Inim control panels.
The driver is also equipped with an "ICP" communication port which
makes it possible to connect to fire alarm signallers from the Iris and Enea
series and configure their operating parameters (select tones/alarm messages,
volume, flasher brightness, etc.). By means of the driver and the
FireGenius-PRO software, it is also possible to create custom tones/messages
for signalling devices either by extracting tones from the vast library
available and composing tones of your liking or starting from audio files.
The kit also allows you to take full advantage of the unique features offered
by LoopMap and Versa ++ technologies integrated into the addressable analogue
detectors of the ENEA series.
The EIKT2000 kit also takes advantage the Versa++ technology,
thanks to which it is possible to manage IRIS series conventional fire
detectors and configure each one in accordance with the specific conditions of
the environment in which it is to be installed. With EITK2000 it is possible to
connect to a line of detectors and, for each of them, carry out a complete
diagnosis to test its functionality, verify the value
read in real time, read the contamination value of the optical chamber, change
its sensitivity and operating mode.
The kit also allows you to read the non-volatile memory, present in every
detector (both Iris and Enea series), which contains a graph with the smoke and
temperature concentrations measured in the period before the last alarm
detected (a function aimed at assisting investigation into the causes that
triggered the alarm).
The device also allows the implementation of accurate diagnoses that identify
where the cable is interrupted or shorted and the carrying out of tests on the
loop (walk tests) which monitor the number of communication errors, record the
date and time of activation of each detector and, on completion of the
operations, provide a printable professional report.
The EDRV2000 driver contained in the EITK2000 kit is capable of operating
autonomously by way of its internal batteries, keypad and display. However,
when the driver is connected to a PC it will be powered and will charge its
batteries through the USB port.
The EITK2000 kit constitutes professional apparatus that the toolbox of every
competent fire professional cannot be without.
The kit comes in a handy case complete with 24Vdc power supply, cable and
software CD.
ENEA series detectors, as a result of advanced technologies based on new-generation microprocessors, represent the most advanced technology that fire detection equipment can offer today.
They provide a vast spectrum of options and flexible functions, all configurable from the control panel (Versa++ technology). ENEA series detectors are capable of implementing a sophisticated set of algorithms, custom created by Inim’s R&D professionals, which ensure unequalled reliability and the highest immunity to false alarms.
Thanks to INIM’s leading-edge LoopMap technology, you can now connect to the control panel by means of a computer or EDRV1000 driver and reconstruct the exact installation topology and obtain an easy-to-use, interactive loop layout map which greatly simplifies and speeds up searches relating to faults and maintenance work.
These detectors have passed - with flying colours - all the tests taken at the LPCB test facility, the prestigious English certification service. And, thus hold the right to use this mark in addition to the obligatory CPD certification for the commercialization of fire detectors.
Parameter |
ED100 |
ED200 |
ED300 |
Operating voltage |
19-30 Vdc |
||
Consumption during standby |
200 uA |
||
Consumption during alarm |
Max 10 mA |
||
Sensitivity |
0.08 – 0.10 – 0.12 – 0.15 dB/m |
A1R (58°C + RoR) – B (72°C) – BR(72°C + RoR) – A2S (58°C) |
0.08 – 0.10 – 0.12 – 0.15 dB/m ------------------------------------- A1R (58°C + RoR) – B (72°C) – BR(72°C + RoR) – A2S (58°C) ----------------------------------------- AND –OR – PLUS Mode |
Operating temperature |
-5°C + 40°C |
||
Height including base |
46mm |
54mm |
|
Diameter |
110mm |
||
Weight (with base) |
160g |
||
Weight (without base) |
90g |